θ
29,00
des
Fmax
Fmax
Fmax
Fmax
Fmax
Fmax
2
2
2
2
2
2
2
Fmax
Fmax
Fmax
Fmax
2
2
2
2
F,m
28,55
95
28,10
90
-
-
15,0 8,7
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
-
-
27,65
85
27,20
80
26,75
75
26,30
70
25,85
65
25,40
60
24,95
55
24,50
50
24,05
45
15,0 10,5
-
15,0 10,5
-
15,0 10,5
-
15,0 10,5
-
15,0 10,5
-
-
-
-
-
-
-
-
-
-
-
15,0 9,4
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
23,60
40
15,0 10,5
15,0 10,5
θ
29,00
28,55
95
28,10
90
27,65
85
F,m
100 15,0 8,2
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
-
-
15,0 10,5
-
-
15,
0
10,5
-
-
-
-
-
-
-
-
-
-
-
-
15,0 7,0
15,0 9,3
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
15,0 10,4
15,0 10,5
15,0 10,5
-
-
-
-
-
-
-
-
-
-
-
-
15,0 7,0
-
15,0 9,9
-
15,0 10,5
-
15,0 10,5
-
15,0 10,5
-
15,0 10,5
-
15,0 10,5
-
15,0 10,5
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
V,des
V,des
V,des
V,des
V,des
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
15,0 7,0
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
-
-
15,0 10,5
temperatura superficiale superiore ai 29°C sulla verticale della tubazione, nel punto mediano del circuito.
I valori evidenziati in grassetto rappresentano il superamento della resa limite per le zone di permanenza secondo UNI EN 1264, ovvero una
V,des
V,des
V,des
V,des
V,des
des
Fmax
Fmax
Fmax
Fmax
Fmax
Fmax
Fmax
Fmax
Fmax
Fmax
2
2
2
2
2
2
2
2
2
2
2
100 15,0 10,5
-
15,0 10,5
-
15,0 10,5
-
15,0 10,5
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
15,0 10,5 15,0 10,5
-
-
15,0 10,5
15,0 6,5 15,0 10,5
15,0 9,2 15,0 10,5
-
-
-
-
-
-
-
-
-
-
15,0 7,2
15,0 10,4
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,1
-
15,0 11,7
-
15,0 13,3
-
15,0 14,9
-
15,0 16,8
-
15,0 18,7
-
15,0 20,8
-
15,0 10,5
-
15,0 10,5
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
15,0 5,8
15,0 8,0
15,0 10,1
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
27,20
80
-
-
15,0 10,5
-
15,0 10,5
-
15,0 10,5
-
15,0 10,5
-
15,0 10,5
-
15,0 10,5
-
15,0 10,5
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
-
-
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
-
-
-
-
-
-
-
-
-
-
26,75
75
-
26,30
70
-
25,85
65
-
25,40
60
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
24,95
55
-
15,0 10,5
15,0 10,5
15,0 10,5
15,0 10,5
15,0 8,3
15,0 10,5
15,0 10,5
15,0 10,5
24,50
50
-
24,05
45
-
23,60
40
-
I valori evidenziati in grassetto rappresentano il superamento della resa limite per le zone di permanenza secondo
temperatura superficiale superiore ai 29°C sulla verticale della tubazione, nel punto mediano del circuito.
UNI EN 1264, ovvero una
V,des
°C
F,m
°C
des
W/m
2
cm
Fmax
m
2
Temperatura di mandata
Temperatura superficiale media, riferita ad una temperatura ambiente di 20°C
Resa termica specifica
Interasse tubazione
Superficie massima circuito