A

Steam traps

Ball float

Steam

saturation

curve

D

C

B

5.5.69

A

D

D

Pressure / temperature limits

A - B

A - C

A - D

The product must not be used in this region.

Flanged EN 1092 PN40, ASME 300.

Flanged JIS/KS 20K.

Flanged ASME 150.

Pressure bar g

Body design conditions

PN40

40 bar g @ 100 °C

300 °C

-10 °C

32 bar g @ 239 °C

300 °C @ 27.5 bar g

-10 °C

4.5 bar

10 bar

21 bar

32 bar

60 bar g

48 bar g

F

Weight

310

95

310

97

B

C

E

Withdrawal

distance

PMA Maximum allowable pressure

TMA Maximum allowable temperature

Minimum allowable temperature

PMO Maximum operating pressure for saturated steam service

TMO Maximum operating temperature

Minimum operating temperature

Note: for lower operating temperatures consult Spirax Sarco

DPMX Maximum differential pressure

FT44-4.5

FT44-10

FT44-21

FT44-32

Designed for a maximum cold hydraulic test pressure of :

Note: With internals fitted, test pressure must not exceed :

Dimensions / weights (approximate) in mm and kg

Size

DN80

DN100

ASME 150 ASME 300

PN40

JIS/KS 20K

A

A

A

A

B

C

123

123

D

E

390

200

390

200

343

350

362

353

366

350

350

350

140

140

F

Page 2 of 4

TI-S02-23 CMGT Issue 13

FT44 Cast Steel Ball Float Steam Traps DN80 and DN100

T

e

m

p

e

r

a

t

u

r

e

°