Steam traps

Ball float

Page 3 of 4

Capacities

������

������

������

������

������

������

������

����

����

����

����

����

����

����

����

����

������

������

������ ������ ������

��

��

��

��

��

����

����

����

Differential pressure bar ( x 100 = kPa )

Additional cold water capacities from thermostatic air vent (TV) under start-up conditions.

Capacities shown above are based on condensate at saturation temperature. Under start-up conditions when the condensate is cold the

internal thermostatic air vent (TV) will be open and provides additional capacity to the main valve. The following table gives the minimum

additional cold water capacities from the air vent.

0.5 1

2

3

4.5

7

10

14 21

DP (bar)

DN15 and DN20

Minimum additional cold water capacity (kg/h)

FTC32 Carbon Steel Ball Float Steam Trap (DN15 and DN20)

32

3 200

70 140

250

380 560

870

1 130

1 500 2 300

TI-P602-01 ST Issue 4

Page 3 of 4

5.5.50

����������������

����������������

��������

C

o

n

d

e

n

s

a

t

e

k

g

/

h

����������������