Page 3 of 4
A
C
B
0.5 1
2 3
4.5 7 10
70
140
250
380
560
870
1 130
120
240
360
500
640
920
1 220
Size
A
B
B1
C
D
E
F
Weight
Withdrawal distance
1⁄2" and 3⁄4"
123
107
96
80
160
120
38
3.4
1"
145
117
117
70
162
120
38
4.6
FTGS14
D
B1
FTGS14-C
F
E
����
����
���
���
���
���
���
��
��
��
��
���
���
���
���
�
�
�
� �
��
��
Differential pressure bar (x 100 = kPa)
Capacities shown above are based on condensate at saturation temperature. Under start-up conditions when the condensate is cold the
internal thermostatic air vent will be open and provides additional capacity to the main valve. The following table gives the minimum additional
cold water capacities from the air vent.
∆P (bar)
1⁄2" and 3⁄4"
1"
Minimum additional cold water capacity (kg/h)
FTGS14 Ball Float Steam Trap (Screwed)
14
1500
1500
TI-P145-11 ST Issue 5
Page 3 of 4
���
��������������
���
��
��
��
�����������������
��
C
o
n
d
e
n
s
a
t
e
k
g
/
h