Weight
Size
1⁄2" DN15
3⁄4" DN20
The spare parts available are shown in heavy outline. Parts drawn
in broken line are not supplied as spares.
A A1 B
95 150 94
E Withdrawal distance
C
F
A
A1
G Withdrawal distance
C E
64 37
F G
63 28
Scrd/SW/BW Flgd
1.65
3.15
1.65
3.75
1.85
4.45
B
Available spares
Capsule and seat assembly set
Strainer screen Y-type cylindrical (1 off)
2, 3, 17, 18
5
7
13, 14
16
95 150 94
1"DN25 95 160 94 64 37 66 28
64 37
64 28
Set of cover gaskets
Sensor and sensor gasket
Adaptor gasket
(packet of 3)
(packet of 3)
C
o
n
d
e
n
s
a
t
e
k
g
/
h
Differential pressure bar (x 100 = kPa)
Hot water capacity
Cold water capacity
For full details see the Installation and Maintenance Instructions
(IM-F01-30) supplied with the product.
Installation note:
5
16
12*
13
14
The IBPS32 is designed for installation with the capsule in a
horizontal plane with the cover at the top.
It is recommended that a non-return valve is fitted when discharging
condensate into return lines where backpressure is experienced. It
is also recommended that a diffuser is fitted when discharging to
atmosphere.
For ease and maintenance, consideration should be given to fitting
isolation valves upstream and downstream of the steam trap.
* Note
Items 9 and 12
are not available as spares
Disposal
The product is recyclable. No ecological hazard is anticipated with
the disposal of this product, providing due care is taken.
Example: 1 off Spirax Sarco 1⁄2" IBPS32 stainless steel bodied
maintainable balanced pressure thermostatic steam trap. Screwed
BSP with 'STD' fill capsule for operation at approximately 12°C below
steam saturation temperature.
The trap will be supplied with an integral sensor to identify
waterlogging and steam wastage (WLS1 sensor) or for steam leakage
only (SS1 sensor). Sensors to be compatible with Spiratec indicators,
automatic monitors and test points:
R1 (single trap) remote test point, R12 (12 trap) remote test point,
Type 30 hand held indicator, R16C (16 traps) automatic steam trap
monitor or R1C (single trap) automatic steam trap monitor with
PNP/NPN output where appropriate.
Item Part
3
Valve seat
9
Cover bolts
12 Sensor adaptor
14 Sensor
or
mm
N m
115 - 125
23 - 27
120 - 135
50 - 56
How to order spares
Always order spares by using the description given in the column
headed 'Available spares' and state the size, model number and
capsule reference.
Example: 1 - Capsule and seat assembly set for a Spirax Sarco
DN25 IBPS32 having 'STD' fill capsule for operation at 12°C
below steam saturation temperature with integral Spiratec sensor.
24 A/F
16 A/F
27 A/F
24 A/F
M10 x 30
9*
17
2
18
3
7