Weight
The spare parts available are shown in solid outline. Parts drawn
in broken line are not supplied as spares.
A A1 B
95 150 94
95 150 94
1"DN25 95 160 94 64 37 66 28
1.85
4.45
E Withdrawal distance
B
C
Size
1⁄2" DN15
3⁄4" DN20
C
E
64 37
F
G
Scrd/SW/BW Flgd
Available spares
Capsule and seat assembly set
Strainer screen Y-type cylindrical (1 off)
F
64 37
64 28
1.65
3.75
63 28
1.65
3.15
2, 3, 17, 18
5
7
13, 14
16
Set of cover gaskets
Sensor and sensor gasket
Adaptor gasket
How to order spares
(packet of 3)
(packet of 3)
Always order spares by using the description given in the column
headed 'Available spares' and state the size, model number and
capsule reference.
Example: 1 - Capsule and seat assembly set for a Spirax Sarco
DN25 IBPC32 having 'STD' fill capsule for operation at 12°C
below steam saturation temperature with integral Spiratec sensor.
A
9*
A1
G Withdrawal distance
� ���
� ���
����
���
���
���
���
���
��
���
���������
�
� ���
��
����
Differential pressure bar (x 100 = kPa)
Hot water capacity
Cold water capacity
For full details see the Installation and Maintenance Instructions
(IM-F01-30) supplied with the product.
Installation note:
The IBPC32 is designed for installation with the capsule in a
horizontal plane with the cover at the top.
It is recommended that a non-return valve is fitted when discharging
condensate into return lines where backpressure is experienced. It
is also recommended that a diffuser is fitted when discharging to
atmosphere.
For ease and maintenance, consideration should be given to fitting
isolation valves upstream and downstream of the steam trap.
Disposal
The product is recyclable. No ecological hazard is anticipated with
the disposal of this product, providing due care is taken.
Example: 1 off Spirax Sarco 1⁄2" IBPC32 carbon steel bodied
maintainable balanced pressure thermostatic steam trap. Screwed
BSP with 'STD' fill capsule for operation at approximately 12°C below
steam saturation temperature.
The trap will be supplied with an integral sensor to identify
waterlogging and steam wastage (WLS1 sensor) or for steam leakage
only (SS1 sensor). Sensors to be compatible with Spiratec indicators,
automatic monitors and test points:
R1 (single trap) remote test point, R12 (12 trap) remote test point,
Type 30 hand held indicator, R16C (16 traps) automatic steam
trap monitor or R1C (single trap) automatic steam trap monitor
with PNP/NPN output where appropriate.
17
2
18
3
7
������
��������
������
C
o
n
d
e
n
s
a
t
e
k
g
/
h
��������
IBPC32 Carbon Steel Balanced Pressure Thermostatic Steam Trap
with Integral Spiratec Sensor
TI-P005-06 ST Issue 4
* Note
Items 9 and 12
are not available as spares
5
16
12*
13
14
Item Part
3
Valve seat
9
Cover bolts
12 Sensor adaptor
14 Sensor
or
mm
N m
115 - 125
23 - 27
120 - 135
50 - 56
24 A/F
16 A/F
27 A/F
24 A/F
M10 x 30