Types SRV461S and SRV463S are direct acting pressure reducing valves with
all wetted parts in AISI 316L/1.4404, 1.4408 and 1.4462 stainless steel. For
steam, liquid or gas applications.
Typical applications include: Clean steam, gas and liquid supplies to centrifuges,
freeze dryers, sterilisers, autoclaves, process tanks, humidifiers and culinary
equipment.
SRV461S
D
Steam
E
A
B
saturation
curve
C
F
Local regulations may restrict the use of this product to below the conditions quoted.
In the interests of development and improvement of the product, we reserve the right to change the specification without notice.
© Copyright 2016
CH Issue 10
T
e
m
p
e
r
a
t
u
r
e
°
C
T
e
m
p
e
r
a
t
u
r
e
°
C
SRV463S
D
Steam
SRV461S
1⁄2", 3⁄4", 1", 11⁄4", 11⁄2" and 2"
Screwed NPT, BSP
DN15, DN20, DN25, DN32, DN40
SRV463S
and DN50
Flanged ASME (ANSI) 150, EN 1092
Body design conditions
SRV461S
SRV463S
PN40
PN16
38barg@38°C
15.2 bar g @ 50°C
300°C @ 23.2 bar g
300°C@9barg
-10°C
190°C @ 10.9 bar g
130°C @ 12 bar g
bar g
bar g
bar g
bar g
bar g
bar g
bar g
G11⁄4" - 2"
DN32 - DN50
50:1
25:1
18:1
12:1
A
B
E
C
F
saturation
curve
SRV461S
Maximum design pressure
SRV463S
Maximum design temperature
SRV461S
SRV463S
Minimum design temperature
Maximum operating temperature
Steam
Liquid and gases
Minimum operating temperature
Note: for lower operating temperatures consult Spirax Sarco
Maximum differential pressure
Designed for a maximum cold
hydraulic test pressure of:
SRV461S
SRV463S
opposite
60 bar g
24 bar g
0.12
0.50
1.10
0.80 - 12.00
Pressure bar g
Pressure bar g
The product must not be used in this region.
The product should not be used in this region or beyond its operating
PN16
The SRV461S and
SRV463S are available
for use within the
downstream pressure
ranges shown.
Note: The pressure
range required needs to
be specified at the time
of order placement:-
range as damage to the internals may occur.
A-B-C Maximum operating conditions for steam
D-E-F Maximum operating conditions for liquids and gases
0.02 - 0.12
0.10 - 0.50
0.30 - 1.10
0.80 - 2.50
2.00 - 5.00
4.00 - 8.00
6.00 - 12.00
-10°C
see the Permissable reduction ratio table
0.02 -
0.10 -
0.30 -
Setting range
(bar g)
Nominal
G1⁄2" - 1"
DN15 - DN25
80:1
40:1
30:1
20:1
diameter
Page 1 of 5