A
F
E
G
Steam
saturation
curve
F
E
Pressure psi g
Pressure bar g
The product must not be used in this region.
An extended cover is required for use in this region.
High temperature packing required for use in this region.
Notes:
1. Where the process fluid temperature is sub-zero and the ambient temperature is below +5 °C (+41 °F), the external moving parts of the
valve and actuator must be heat traced to maintain normal operation.
2. When selecting a valve with a bellows scaled bonnet, the pressure / temperature limits of the bellows must be read in conjunction with
the valve pressure / temperature limits shown in table below.
A-E-E
A-F-F
A-G
Page 6 of 17
Body design conditions
PMA Maximum allowable pressure
and
PMO Maximum operating pressure
TMA Maximum allowable temperature
Minimum allowable temperature
TMO Maximum operating
Standard packing PTFE chevron (P)
102.1 bar g @ 38 °C
425 °C @ 57.5 bar g
-29 °C
250 °C @ 83.6 bar g
425 °C @ 57.5 bar g
-29 °C
156 bar g
ASME 600
1480 psi g @ 100 °F
797 °F @ 834 psi g
-20 °F
482 °F @ 1212 psi g
797 °F @ 834 psi g
-20 °F
2 262 psi g
ASME 300
740 psi g @ 100 °F
797 °F @ 418 psi g
-20 °F
482 °F @ 608 psi g
797 °F @ 418 psi g
-20 °F
1 117 psi g
ASME 150
284 psi g @ 100 °F
797 °F @ 80 psi g
-20 °F
482 °F @ 175 psi g
797 °F @ 80 psi g
-20 °F
1 117 psi g
temperature
High temperature packing (H)
Minimum operating temperature
Design for a maximum cold hydraulic test pressure of:
Body design conditions
PMA Maximum allowable pressure
and
51.1barg@38°C
PMO Maximum operating pressure
TMA Maximum allowable temperature
Minimum allowable temperature
TMO Maximum operating
Standard packing PTFE chevron (P)
425 °C @ 28.8 bar g
-29 °C
250 °C @ 41.9 bar g
425 °C @ 28.8 bar g
-29 °C
77 bar g
temperature
High temperature packing (H)
Minimum operating temperature
Design for a maximum cold hydraulic test pressure of:
Body design conditions
PMA Maximum allowable pressure
and
19.6barg@38°C
PMO Maximum operating pressure
TMA Maximum allowable temperature
Minimum allowable temperature
TMO Maximum operating
Standard packing PTFE chevron (P)
425 °C @ 5.5 bar g
-29 °C
250 °C @ 12.1 bar g
425 °C @ 5.5 bar g
-29 °C
77 bar g
temperature
High temperature packing (H)
Minimum operating temperature
Design for a maximum cold hydraulic test pressure of:
TI-P405-51 AB Issue 1
T
e
m
p
e
r
a
t
u
r
e
°
F
T
e
m
p
e
r
a
t
u
r
e
°
C