The full lift capacities for safety valve sizing purposes is 0.21 Kvs.
For any specified primary filtration pressure, there is a maximum recommended air flowrate. Keeping within this, will ensure that the
element performance maintains the stated high efficiency levels.
Air flow scfm
Air flow dm
3
/s
The graph utilises some typical values for secondary flow/pressure to demonstrate droop
Droop =
Pressure droop
@ Relevant flowrate
Set point
For full details see the Installation and Maintenance Instructions (IM-P504-06) supplied with the product.
Warning
Polycarbonate bowls are attacked by phosphate ester fluids, solvents, paint thinners and carbon tetrachloride. These and similar substances
should never be allowed to come into contact with the bowl. Certain compressor lubricating oils also contains additives harmful to polycarbonate
and, where there is any doubt we recommend, in the interests of safety, that a bowl guard be fitted.
Installation note:
Fit in a horizontal pipe, with the bowl vertically downwards, as close as possible to the equipment it is serving. Connect the unit so that the air
flow is in the direction shown by the arrow cast on the body. A pressure guage fitted to one of the ports is recommended (to show the secondary
pressure). The port(s) not in use should be blanked off with the plugs supplied.
Panel mounting:
The panel must not exceed 8 mm thick. The required hole is 31 mm diameter.
Please state quantity, size and type and any options which are required. Unless otherwise stated, the filter/regulator will be supplied with
the 0.7 - 9.0 bar g control spring and a polycarbonate bowl with drain.
Example:
1 off MP2M Monnier self-relieving miniature compressed air filter / regulator having a 0.2 - 2.0 bar g control spring and 1⁄4" BSP connections.
1 off Bowl guard.
Page 3 of 4