- The MP2M, MPN2M regulators are also available as
airsets consisting of Type 8 bracket, mounting ring and pressure
gauge (see options below).
The filter/regulator can be mounted using a zinc plated mild steel
bracket and aluminium mounting ring (not shown). Both items must
be specified when placing an order.
With system pressure on, the regulator poppet valve assembly
is in the closed position when the adjusting knob is turned fully
counter clockwise (no spring load). By turning the adjusting knob
clockwise, the diaphragm/piston moves downward allowing
filtered air to flow in through the orifice created between the poppet
assembly and seat. The control diaphragm/piston offsetting the
load spring senses pressure downstream. Increasing downstream
pressure causes the poppet assembly to move upward until the
load of the spring and diaphragm / piston are balanced. The outlet
pressure has now been reduced. If a valve is opened downstream,
the increased demand for pressure creates a reduced pressure
under the control diaphragm / piston. The poppet assembly moves
downward due to the load of the control spring opening the seat
area and air is allowed to meet the downstream pressure demand.
Thus, the area of the opening meters the downstream flow.
Dimensions (approximate) in millimetres
38
12.7
12.7
31
10
29
64
51
Available in two sizes, with 4 pressure ranges. The face is marked
in both bar and psi. Please state, size and pressure range when
placing an order.
Pressure ranges
Dimensions (approximate) in millimetres
11⁄2" version 40 mm
2" version 48 mm
0 to 2 bar
0 to 7 bar
0 to 11 bar
0 to 21 bar
0 to 30 psi
0 to 100 psi
0 to 160 psi
0 to 300 psi (2" size only)
R"
11⁄2" version 47 mm
2" version 45 mm
With chromium plated bezel available in two ranges, the face being
marked in bar and psi as follows:-
Pressure ranges
0 to 2 bar
0 to 30 psi
0 to 7 bar
0 to 100 psi
Dimensions (approximate) in millimetres
A
B
C
D
53
56
48
R
D
Clamping yoke
A
C
In the interest of safety Spirax Sarco
recommend that a bowl gaurd
should be fitted. See the 'Warning'
under 'Safety information,
installation and maintenance'.
B
5
Page 2 of 4