Pipeline ancillaries

Strainers and filters

Kv values

For conversion: Cv (UK) = Kv x 0.963

Cv (US) = Kv x 1.156

Size

DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200

Perforations 0.8, 1.6 and 3 mm

5

8

13

22

29

46

72

103

155

237

340

588

Mesh 40 and 100

5

8

13

22

29

46

72

103

155

237

340

588

Mesh200

4

6

10

17

23

37

58

83

124

186

268

464

Dimensions / weights (approximate) in mm and kg

Spare parts

The spare parts available are shown in solid outline. Parts drawn in

broken line are not supplied as spares.

Available spares

Cap gasket

DN125 to DN200 (1 off)

3

How to order spares

Always order spares by using the description given in the column

headed 'Available spares' and state the size and type of strainer and

perforation or mesh required.

Example: 1 - Strainer screen, stainless steel having 0.8 mm

perforations for a DN50 Spirax Sarco Fig 3716 strainer PN16.

Size

A

DN15

130

DN20

150

DN25

160

DN32

180

DN40

200

DN50

230

DN65

290

DN80

310

DN100

350

DN125

400

DN150

480

DN200

600

150

-

-

-

-

-

233

288

311

345

396

482

610

Upstream

pressure

tapping

B

69

82

90

114

127

150

162

178

210

253

293

375

Weight

PN16 ASME

Screening

C

area cm2

101

28

125

46

140

79

198

135

210

161

9.0

2.1

2.9

3.8

6.6

Strainer screen

(state: perforations or mesh and size of strainer)

4

DN15 to DN100 (packet of 3)

3

248

251

263

325

17.5

272

360

20.0

323

540

24.0

393

840

38.0

454

1 115

50.5

584

1 905

88.0

Downstream

pressure

tapping

10.5

B

3

4

5

(not an available spare)

Recommended tightening torques

Item

5

A

Withdrawal distance C

Safety information, installation and maintenance

For full details see the Installation and Maintenance Instructions

(IM-S60-18) supplied with the product.

Installation note:

The strainer should be installed in the direction of flow, as

indicated on the body. On applications involving steam or gases

the pocket should be in the horizontal plane. On liquid systems the

pocket should point downwards. Suitable isolation valves must

be installed to allow for safe maintenance and trap replacement.

Maintenance note:

Maintenance can be completed with the strainer in the pipeline.

Disposal

The product is recyclable. No ecological hazard is anticipated

with disposal of this product, providing due care is taken.

How to order

Example: 1 off Spirax Sarco DN40 Fig 3716 strainer, flanged

EN 1092 PN16 with austenitic stainless steel screen having

0.8 mm perforations and flanged screen cap.

N m

15 - 20

15 - 20

15 - 20

22 - 25

22 - 25

22 - 25

50 - 60

50 - 60

50 - 60

100 - 110

Size

Qty

or

mm

DN15 and DN20

DN25

DN32 and DN40

DN50

DN65

DN80

DN100

DN125

DN150

DN200

4

4

4

4

4

6

6

8

8

8

13

13

13

17

17

17

19

19

19

24

M8 x 20

M8 x 20

M8 x 20

M10 x 25

M10 x 30

M10 x 30

M12 x 35

M12 x 40

M12 x 40

M16 x 50

Fig 3716 SG Iron Strainer - DIN Material

TI-P081-03 ST Issue 7

7.7.52