Available types:
DRV7 and DRV7G are available in 6 pressure ranges (suffix 1-6).
Downstream pressure ranges:
Actuator
type
1
DRV7(G)B1(N)
2
DRV7(G)B2(N)
3
DRV7(G)B3(N)
4
DRV7(G)B4(N)
5
DRV7(G)B5(N)
6
DRV7(G)B6(N)
* DN32 to DN50 Range 0.15 - 0.6, DN65 to DN100 Range 0.3 - 0.6
**DN65 to DN100 Range 0.4 - 1.2.
1⁄2", 3⁄4" 1", 11⁄4", 11⁄2", and 2"
Screwed BSP (BS 21 parallel), NPT also available on request.
DN15, DN20, DN25, DN32, DN40, DN50, DN65, DN80 and DN100.
Standard flanges: EN 1092 PN16 and PN25
Flanges available on request: ASME 150 and JIS
A
B
C
D
Range Valve type
Spring
colour
PN
Rating
H
Steam
saturation
curve
A - D - E
A - C - G
A - B - F
H- H
Screwed and flanged EN 1092 PN25.
Flanged EN 1092 PN16.
Flanged ASME 150.
The DRV7G is limited to 90°C.
H
G
F
E
Body design conditions
Maximum design pressure
Maximum design temperature
Minimum design temperature
Maximum operating temperature
Minimum operating temperature
PN25
25 bar g @ 100°C
DRV7
300°C @ 17.5 bar g
DRV7G
90°C @ 25 bar g
0°C
DRV7
300°C @ 17.5 bar g
DRV7G
90°C @ 25 bar g
1 or 1N
2 or 2N
3 or 3N
4 or 4N
5 or 5N
5 or 5N
Yellow
Yellow
Blue
Blue
Blue
Red
(bar)
*0.1-0.6
2.5
Pressure bar g
The product must not be used in this region.
0°C
Note: For lower operating temperatures consult Spirax Sarco
Size DN 15
20 25
Kvs
3.4 6.5 11.4 16.4 24 40
58 92 145
Maximum differential pressure
DN15-DN50
25 bar
DN65-DN100
20 bar
Designed for a maximum cold hydraulic test pressure of 38 bar g
Note: With internals fitted, test pressure must not exceed 25 bar g
32
40 50 65
Note: The Kvs values shown above are full capacities and should
Local regulations may restrict the use of this product to below the conditions quoted.
In the interests of development and improvement of the product, we reserve the right to change the specification without notice.
© Copyright 2013
The DRV7 is an SG iron direct acting bellows sealed pressure reducing valve. The standard version has an EPDM diaphragm and is
suitable for steam, water and air applications. The DRV7 is available with a Nitrile rubber diaphragm (suffix 'N') for oil applications.
A Nitrile rubber soft seated version (suffix 'G', limited to 90°C) is also available for applications that require tight shut-off. It is recommended
that for these applications a maximum pressure turndown ratio of 10:1 is observed.
Note: To protect the actuator diaphragm on steam applications a WS4 water seal pot must be installed in the downstream pressure
signal line to the actuator. Refer to TI-S12-03 for details.
Pressure
range
**0.2-1.2
2.5
0.8-2.5
6.0
2.0-5.0 16.0
4.5-10.0 25.0
8.0-20.0 25.0
be used for safety valve sizing purposes where they are required.
CH Issue 14
T
e
m
p
e
r
a
t
u
r
e
°
C
80 100
Page 1 of 6