ISO 9001
E
D
F
Steam
saturation
curve
Screwed
A
160
160
180
-
-
-
-
BS 10 H
A1
-
-
160
180
200
230
-
PN16 / 25
A1
130
150
160
180
200
230
PN40
310
ANSI 300
A1
126.6
-
160.0
180.0
200.0
230.0
319.0
BS 10 F
A1
117
133
-
-
-
-
BS 10 J
325
ANSI 150
A1
120.2
139.4
160.0
176.0
199.0
228.0
310.0
JIS 10/16
A1
122
142
152
176
196
222
-
B
185
185
207
207
255
255
350
D
301
301
325
325
369
369
473
E
171
171
177
177
191
191
215
F
130
130
148
148
178
178
259
11.0
11.0
12.0
-
Cert. No. LRQ 0963008
The HL17 high limit cut-out is a solenoid operated shut-off valve
which can be activated by any device capable of interrupting the
supply of current to the solenoid coil, such as a thermostat.
DN15, 20, 25, 32, 40, 50 and 80
Screwed BSP (BS 21 parallel) or API (DN15 to 25 only)
A
A1
DN15 -
Flanges
DN25 -
DN80 -
DN15 -
DN15 -
DN15 -
DN80 -
DN15 - 50
PN25
DN80
PN40
190°C
10barg
DN15-50
38barg
cold hydraulic test pressure of:
DN80
60 bar g
Also available
50 EN 1092 PN16 and PN25
50 BS 10 Table H and ANSI 300
EN 1092 PN40 and ANSI 300
50 JIS 10/16 and ANSI 150
20 BS 10 Table F
ANSI 300
JIS 20, BS 10 Table J and ANSI 150
Body design conditions
Maximum design temperature
Maximum operating pressure
Designed for a maximum
B
Pressure bar g
220 / 240 ±10% Vac or 110 / 120 ±10% Vac
(others available on request).
Using the saturated steam sizing chart from TI-GCH-03, establish
the required Kv and then select the next highest valve Kv from the
table below.
DN15
DN20
DN25
DN32
DN40
DN50
DN80
4.0
6.2
9.5
16
22
30
75
Voltages available
Frequency
50 / 60 Hz
Power consumption
Inrush
45 VA
Holding
23 VA
For conversion:
Cv (UK) = Kv x 0.963
Cv (US) = Kv x 1.156
Weight
Screwed Flanged
11.8
12.7
15.0
16.0
28.0
30.5
100.0
© Copyright 2004
Size
DN15
DN20
DN25
DN32
DN40
DN50
DN80
Local regulations may restrict the use of this product to below the conditions quoted.
In the interests of development and improvement of the product, we reserve the right to change the specification.
T
e
m
p
e
r
a
t
u
r
e
°
C