Temperature range
PN9100
PN9200
PN9300
Air supply connection
PN9100
- 20 °C to +110 °C
6barg
6barg
4barg
1⁄4" NPT
20 mm
K
20 mm
30 mm
Maximum operating
inlet pressure
Actuator travel
G
PN922_
PN923_
J
H
and PN932_
and PN933_
H
Actuator range
PN9100E and variants
PN9100R and variants
PN9200E and variants
PN9200R and variants
PN9230E and variants
PN9230R and variants
PN9320E and variants
PN9320R and variants
PN9330E and variants
PN9330R and variants
PN9336E and variants
PN9336R and variants
PN9337E and variants
PN9337R and variants
F
G
J
H
(Handwheel
K
lifted)
Actuator
With handwheel
+ 5.86
+ 2.50
+ 7.20
+ 3.77
+ 3.77
+ 3.77
+ 7.20
+ 3.77
+ 7.20
+ 3.70
+ 7.20
+ 3.77
+ 21.00
+ 21.00
275
170
55
275
170
120
300
300
65
300
300
132
335
300
65
335
300
122
325
390
65
325
390
132
335
390
65
335
390
122
335
390
65
335
390
122
335
390
410
335
390
410
75
225
6
140
225
6
85
350
17
152
350
17
95
350
17
152
350
17
85
350
27
152
350
27
95
350
27
152
350
27
95
350
27
152
350
27
410
350
27
410
350
27
K
F
F
F
G
G
Weight
The following tables supply guidance as to the sizing of the PN9000 when it is used on a Spira-trol
TM
control valve.
Two conditions are illustrated in tabular form:
Class IV shut-off - Providing shut-off of the valve to the requirements of BS 5793-4 (IEC 60534-4) class IV.
Class VI shut-off - Providing shut-off of the valve to the requirements of BS 5793-4 (IEC 60534-4) class VI.
To select a suitable actuator:
Identify the column containing the valve and gland material selected.
Identify the maximum operating pressure condition, including any transient pressures likely to occur, within the selected column.
Read back to the left hand side of the table to identify the suitable actuator for the application.
For conditions outside of those illustrated please contact Spirax Sarco.
TI-P357-30 CH Issue 10
Page 3 of 26
TM