Control valves

Control valves

Pressure / temperature limits - LE31 and LE33 cast iron valve body

300

Note:

Screwed BSP

Flanged EN 1092 PN16

250

When the process fluid temperature

200

is sub-zero and the ambient

150

temperature is below +5 °C, the

100

external moving parts of the valve

50

and actuator must be heat traced

0

to maintain normal operation.

-10

0

2

4

6

8

10

12

14

16

Pressure bar g

Flanged JIS / KS 10

Body design conditions

Maximum design pressure

Maximum design temperature

Maximum differential pressure design

Minimum design temperature

Maximum operating temperature

See the Spira-trol

TM

selection

guide on page 18 for the full list

of available options

Minimum operating temperature

Maximum differential pressures

Pressure bar g

The product must not be used in this region.

High temperature graphite packing is required for use in this region. Note: Soft seated valves cannot be used in this region.

PTFE soft seated valves are limited to a maximum operating temperature of 200 °C.

PN16

16 bar g @ 120 °C

300 °C @ 9.6 bar g

7 bar

7 bar

19 bar

-10 °C

250 °C

200 °C

250 °C

300 °C

250 °C

300 °C

300 °C

-10 °C

24 bar g

TI-S24-70 CH Issue 6

Spira-trol

TM

Two-port Control Valves EN Standard LE, LF and LL DN15 to DN100 and ASME Standard LEA, LFA and LLA 1⁄2" to 4"

Maximum cold hydraulic test pressure of:

Steam

saturation

curve

PTFE soft seat (G)

PEEK soft seat (K)

Full PEEK seat (P)

Standard packing PTFE chevron

PTFE soft seat

PEEK soft seat

Graphite packing

Extended bonnet with PTFE chevron

Extended bonnet with graphite packing

Bellows

Note: For lower operating temperatures

- Option P

- Option G

- Option K

- Option H

- Option E

- Option E

- Option D

or N

or P

Steam

saturation

curve

consult Spirax Sarco

See relevant actuator Technical Information sheet.

Page 7 of 18