Size
A
B
C
D
E
F
Weight
For full details see the Installation and Maintanence Instructions
(IM-P144-02) supplied with the product.
The CA14 must be installed with the direction of flow as indicated on
the body, and with the float arm in a horizontal plain so that it rises
and falls vertically.
Disposal
If a product which contains a Viton component has been subjected
to a temperature approaching 315°C or higher, then it may have
decomposed and formed hydrofluoric acid. Avoid skin contact and
inhalation of any fumes as the acid will cause deep skin burns and
damage to the respiratory system. Viton must be disposed of in a
recognised manner as stated in the Installation and Maintenance
Instructions. No other ecological hazard is anticipated with the
disposal of this product providing due care is taken.
Example: 1 off Spirax Sarco 1⁄2" CA14 having screwed BSP
connections with SG iron body and cover.
1⁄2"
3⁄4"
147
147
D
F
114
114
80
114
105
80
114
105
60.5
2.5
60.5
2.5
A
C
Differential pressure bar (x 100 = kPa)
Withdrawal
E
distance
Installation note:
B
The spare parts available are shown in heavy outline. Parts drawn
in broken lines are not supplied as spares.
Available spares
Maintenance kit
Seal kit
CA14
3, 5+9, 6, 7, 8 (2 off), 10, 11
CA14S
3, 5+9, 6, 7, 8 (2 off), 10, 11
CA14
3, 5
How to order spares
Always order spares by using the description given in the column
headed 'Available spares' and state the size and type of trap.
Example: 1 off Maintenance kit for a Spirax Sarco 1⁄2" CA14 air and
gas trap.
2
Not an
available
spare
7
6
10
11
58
9
N m
47 - 50
50 - 55
2.5 - 3.0
Item
2
6
8
or
mm
3
17 A/F
M10 x 30
17A/F
Pozidrive
M4 x 6
C
o
n
d
e
n
s
a
t
e
k
g
/
h