Size
A
B
C
D
E
F
G
L
Weight
Empty
Full
of water
M3-8
480
180
M3-10
480
180
M3-21
480
180
M3-31
480
180
M6-12
920
320
M6-15
920
320
M6-19
920
320
M6-21
920
320
M6-25
920
320
M6-33
920
320
357
357
357
357
640
640
640
640
640
640
G
60
60
60
60
140
140
140
140
140
140
L
62
62
62
62
140
140
140
140
140
140
11⁄4"
60
300
11⁄4"
60
300
11⁄4"
60
300
11⁄4"
60
300
2"
60
585
2"
60
585
2"
60
585
2"
60
585
2"
60
585
2"
60
585
32
32
35
40
97
100
104
106
110
120
B
D
When the heat exchanger is used as part of the Spirax Sarco boiler
blowdown heat recovery system - refer to the appropriate literature.
Otherwise:
A
F
C
E
Plate heat exchanger
Type
M3-8
M3-10
M3-21
M3-31
M6-12
M6-15
M6-19
M6-21
M6-25
M6-33
Maximum blowdown capacity
(kg/h)
648
860
1 450
2160
2 750
4 900
5915
7110
8040
11 000
10
21
31
12
8
31
31
34
37
This document does not contain enough information to install the product / system safely. For full details see the Installation and Maintenance
Instructions supplied with the product.
Installation notes:
The preferred method of installation is to bolt the heat exchanger rigidly to the floor, in a vertical position. We recommend the use of a
swan neck on the primary outlet (S2) to ensure the heat exchanger does not dry out - this can otherwise cause problems with debris and
can damage the gaskets.
Maintenance note:
An annual inspection is recommended to check for leaking gaskets and the build up of scale and sludge.
Spare plates with integral gaskets are available from Spirax Sarco.
Example: 1 off M6-23 plate heat exchanger having 2" screwed ISO R connections.
Number
of
plates
15
19
21
25
33
94
96
99
100
103
111
S4 S1
S3 S2