Pipeline ancillaries

Pressure gauges and temperature gauges

7.11.1

ISO 9001

TI-P027-01

ST Issue 13

Cert. No. LRQ 0963008

Description

Pressure gauge with 100 mm diameter dial with units marked in

bar, psi and inches hg for vacuum as appropriate and having a

BSP connection. The gauge is supplied with either:

Ring type syphon tube and cock or a 'U' type syphon tube and

cock.

Bourdon tube gauge, constructed in accordance with DIN 16005.

For the following options, consult Spirax Sarco:

Pressure gauges with NPT connections.

A dial with MPa units is available where indicated (

*) in the

'Available pressure range' table below.

BSP Pressure Gauge

with Syphon and Cock

Available pressure range

Range

0to1.6 bar

0to4.0 bar

0to6.0 bar

0to23psi

0to53psi

0to86psi

Steel

Note: Where

indicated (

*)

a dial with

MPa units is

available.

Stainless steel

Standards

Range

*

Range

*

Range

*

Range

Range

Range

Range

Range

Range

Range

Range

Range

Range

0 to

0 to

0 to

0 to

-1 to

-1 to

-1 to

10.0 bar

16.0 bar

25.0 bar

40.0 bar

1.5 bar

3.0 bar

5.0 bar

0

0

0

0

30" Hg

30" Hg

30" Hg

to 145 psi

to 230 psi

to 360 psi

to 580 psi

to 20 psi

to 40 psi

to 70 psi

*

*

0 to 4.0 bar

0 to 10.0 bar

0 to 16.0 bar

0 to 25.0 bar

0to53psi

0to145psi

0to230psi

0to360psi

The product fully complies with the requirements of the Pressure

Equipment Directive 97/23/EC.

Certification

A certificate of conformity is available as standard for this product.

A calibration certificate is available by special order at extra cost.

Sizes and pipe connections

Pressure/temperature limits

Maximum design conditions

PMA Maximum allowable pressure

Pressure gauge

Gauge cock

Ring/'U' syphon

Cock end

Process end

Materials - Steel

Part

Gauge

Ring and 'U' syphon

Body

Handle

(BS 2779)

(BS 2779)

(BS 21)

(BS 21)

(BS 21)

Gauge end

Syphon end

" BSP male

" BSP female

" BSP female parallel

" BSP male taper

" male parallel

Full scale reading

Full scale reading

TMA Maximum allowable temperature of gauge

217°C

Note: Either a 'U' or a ring syphon must be fitted to achieve this.

Minimum allowable temperature

-40°C

20 psi

23 psi

40 psi

53 psi

70 psi

86 psi

145 psi

230 psi

360 psi

580 psi

60°C

Material

Pressed steel

Snap fit perspex

CuSh 8 (92% Cu 8% Zn)

Mild steel tube BS 1387 heavy grade

Brass

Phenolic

PMO

Range †

Range

Maximum operating pressure Range †

Please note:

Range

1. Where indicated (†) these Range †

units are available as

compound gauges down to Range

full vacuum.

Range

2. For compressed air and

steam services the maximum Range

operating pressure for this

Range

product is 21 bar g.

1.5 bar

1.6 bar

3 bar

4 bar

5 bar

6 bar

10 bar

16 bar

25 bar

40 bar

Case

Glass

Bourdon tube

Gauge cock

Materials - Stainless steel

Gauge

'U' syphon

Gauge cock

Case

Glass

Bourdon tube

Use a Spirax Sarco

Stainless steel

Snap-fit perspex

Stainless steel 316TI

Stainless steel

" M10S4 Stainless steel

Range

Maximum ambient temperature

Local regulations may restrict the use of this product to below the conditions quoted.

In the interests of development and improvement of the product, we reserve the right to change the specification without notice.

© Copyright 2006