Basic dimensions

1

Main flow

2

Thermometer

3

Draft regulator openings

4

Upper boiler door

5

Lower boiler door

EKO-CKP

2

1

TEHNIKA GRIJANJA

3

3

4

5

6

EKO-CK P 14-110 kW

230

6

7

8

9

Pellet / fuel oil burner

installation opening

Primary air flap

Pump thermostat connector

Thermal protection mount

openings (1" female thread)

10

Flue gas tube

11

Fluegasboxcleaningopening

12

Return flow

13

Filling/draining

8

9

9

10

11

12

F

G

B

14

20

25

30

35

40

50

60

70

90

110

Ratedheatoutput

(kW)

14

15-20

20-25

25-30

30-35

35-40

40-50

50-60

50-70

70-90

90-110

Boilerwatercontent

(l)

59

60

64

67

76

78

96

118

135

140

157

(kg)

220

227

234

255

266

293

337

355

429

455

492

Boilermass

Flue gas tube diameter*/height (G)

Burner opening (h x w)

Upper boiler door opening (h x w)

Lower boiler door opening (h x w)

Chimneyunderpressure

(Pa)

15

16

18

19

20

21

23

25

26

29

31

Main/Returnflow

(R)

5/4"

5/4"

5/4"

5/4"

985

985

1020

1020

1255

1255

1255

1255

Ø (mm)

150/930

(mm)

170x165

(mm)

321x273

(mm)

321x322

150/930

150/930

170x165

170x165

321x273

321x273

321x322

321x322

160/930

160/930

170x165

170x165

371x273

421x273

371x322

421x322

180/930

180/930

210x165

210x165

471x273

471x273

471x322

471x322

180/1025

210x165

471x273

471x322

200/1085

210x165

471/275

471/422

200/1085

210x165

521/275

521/422

200/1085

210x165

521/275

521/422

Filling/draining

(R)

1/2"

1/2"

Flue gas temperature (fuel oil)

(°C)

170

170

Flue gas temperature (wood)

(°C)

190

190

Max.operatingtemperature

(°C)

90

90

90

90

90

90

90

90

90

90

90

Max.operatingoverpressure

(bar)

2,5

2,5

2,5

2,5

2,5

2,5

2,5

2,5

2,5

2,5

2,5

BoilerdepthA

BoilerheightB

Boiler body width C

Total boiler width D

Boiler base depth E

Return flow connection height F

Max.loglength

(mm)

420

420

470

470

565

565

485

485

500

500

420

470

470

520

600

600

485

485

500

500

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

1020

1020

1142

1142

1255

1255

1255

1355

520

570

570

570

570

620

620

620

600

600

725

725

485

485

485

485

500

500

500

500

1250

1250

1350

1430

1430

1430

570

620

620

640

690

690

815

815

915

630

630

630

500

500

500

1/2"

1/2"

170

170

190

190

190

200

200

230

240

240

Energyefficiencyclass

A

A

A

A

A

A

A

A

A

A

A

* The inner diameter of the chimney is determined according to the power of the boiler and the height of the chimney and must almost always be larger than the diameter of the flue gas tube

5/4"

5/4"

5/4"

5/4"

1/2"

1/2"

1/2"

1/2"

170

170

180

180

190

190

220

220

6/4"

2"

2"

1"

1"

1"

7

13

C

E

D

A