Technical data

TB 120-150

TB 200-850

TB 120-850 LIT.

TB

performance

1)

(kW)

120

150

200

300

600

850

Volume

(l)

121

150

Max. heat exchanger 80°C

16,6

21,0

(l/h)

408

515

70°C

(kW)

13,3

19,0

330

417

60°C

(l/h)

(kW)

8,3

10,5

Water heater water flow

(l/h)

204

257

(m3/h)

1,5

1,5

Tube heat exchanger

Tube heat exchanger water content

Water heater mass

(m2)

0,42

0,53

(l)

1,9

2,4

(kg)

30

41

Outer diameter A

Ø (mm)

640

640

Water heater height B

(mm)

970

1125

HeightsD/E/F

(mm)

92/-/-

92/-/-

Heights G / H

Max. operating DHW overpressure

(mm)

(bar)

-

-

Cold / hot water connection

(R)

3/4"

3/4"

6

6

Max. operating heating medium overpressure

(bar)

6

6

Energy efficiency class

L

C

C

200

33,1

814

26,7

658

16,5

406

1,5

0,84

2,8

46

640

1450

92/300/810

920/1150

3/4"

294

545

860

52,6

82,9

124,0

1297

2045

3067

39,5

63,0

94,5

975

1554

2331

24,5

39,0

58,5

604

962

1443

5,0

5,0

5,0

1,3

2,1

3,15

7,2

11,6

17,5

63

129

157

640

810

960

1900

1995

1940

92/300/950

100/390/1100 72/325/1075

1060/1650

1200/1710

1375/1640

3/4"

5/4"

5/4"

1

Hot DHW connection

2

Recirculation

3

Temp. sensor location

4

Cold DHW connection

5

Thermal insulation

6

Tube heat exchanger

7

Cleaning opening (TB 120-150)

8

Water heater drain connection

9

Water heater stand stand

10

Water heater heating medium connection - flow

11

Water heater heating medium connection - return

12

Thermometer

13

Cleaning opening (TB-200-850)

6

6

6

6

6

6

6

6

C

C

C

C

(1) Inlet temp. heating medium 80,70,60°C; DHW 10/45°C