System separation DN 25 (1") for HeatBloC®s

Application examples

The heating circuits recommended for combination with the system separations (36533, 36553, 36573) are listed on this page. Equipment and prices of the

heating circuits can be found on pages K31, K32 and K34.

Note: the heating circuits have to be ordered seperately. The assembly must be carried out on-site!

Application 1:

Extension of already existing heating circuits / installations with a temperature control on the primary side (mixed heating circuit with controlled

flow

temperature or modulating boiler with boiler circuit pump).

Mounting example

Heating circuit

Pump

EEI*

System separation

Range of performance**

+

K31

+

K34

36013WP6

36013GH6

36013GM6

36063WP6

36063GH6

36063GM6

prim. 36053MWP6

sec. 36013WP6

prim. 36053MGH6

sec. 36013GH6

prim. 36053MGM6

sec. 36013GM6

Wilo Para 25/6-43

≤ 0.2

Grundfos ALPHA2.1

25-60

≤0.17

Grundfps UPM3 Auto L

≤ 0.2

25-70 PP3

Wilo Para 25/6-43

≤ 0.2

Grundfos ALPHA2.1

≤0.17

25-60

Grundfos UPM3 Auto L

≤ 0.2

25-70 PP3

Wilo Para 25/6-43

≤ 0.2

Grundfos ALPHA2.1

25-60

36533

36553

36573

36533

36553

36573

36533

36553

36533

36553

36573

36533

36553

36573

36533

36553

36533

36553

36533

36553

36533

36553

1580 l/h = 18.3 kW

1830 l/h = 21.2 kW

1930 l/h = 22.4 kW

1480 l/h = 17.2 kW

1710 l/h = 19.9 kW

1790 l/h = 20.8 kW

1720 l/h = 20.0 kW

2020 l/h = 23.5 kW

1540 l/h = 17.9 kW

1780 l/h = 20.7 kW

1860 l/h = 21.6 kW

1450 l/h = 16.8 kW

1650 l/h = 19.2 kW

1730 l/h = 20.1 kW

1690 l/h = 19.6 kW

1950 l/h = 22.6 kW

1540 l/h = 17.9 kW

1750 l/h = 20.3 kW

1440 l/h = 16.7 kW

1630 l/h = 18.9 kW

1670 l/h = 19.4 kW

1930 l/h = 22.4 kW

36573

2120 l/h = 24.6 kW

Application 2:

Extension of already existing heating circuits / installations with a pump on the primary side and high

flow temperatures (bypass operation in addition to

the radiator circuits or operation with solid fuel boiler and boiler circuit pump).

Mounting example

Heating circuit

Pump

EEI*

System separation

Range of performance**

36573

2030 l/h = 23.6 kW

Application 3:

Complete system separation with mixing valve control on the primary side. Ensures low return temperatures of the boiler and allows the operation of

several parallel heating circuits, f. ex. on a distribution manifold.

Mounting example

Heating circuit

Pump

EEI*

System separation

Range of performance**

36573

1830 l/h = 21.2 kW

K31

+

K32

≤0.17

36573

1710 l/h = 19.9 kW

36573

2000 l/h = 23.2 kW

Grundfps UPM3 Auto L

≤ 0.2

25-70 PP3

** At a primary temperature of 60 - 50 °C, a secondary temperature of 35 - 45 °C and a secondary residual head of 1.5 m wc

01/2024 • Printed in Germany

PAW GmbH & Co. KG • info@paw.eu • www.paw.eu