Unità esterne VRF innovative dotate di Intelligenza Artificiale nativa (AI),
nuovo Compressore con Advance Flash Injection (AFI
TM)
e ventilatore a profilo variabile.
DETRAZIONI
FISCALI*
CONTO
TERMICO*
1,695mm
930mm
1,295mm
765mm
MODELLO
56 HP (12+18+26)
58 HP (12+20+26)
60 HP (12+22+26)
3, 4, 380-415, 50
3, 4, 380-415, 50
3, 4, 380-415, 50
Pompa di Calore
Pompa di Calore
Pompa di Calore
64
56
64
64
58
60
156.8 / 156.8
(1)
162.4 / 162.4
(1)
168.0 / 168.0
(1)
176.4 / 152.0
(1)
182.7 / 157.6
(1)
189.0 / 163.2
(1)
103.65
115.49
121.01
80.62
85.20
86.77
124.2
128.0
131.0
150
150
150
-
-
-
-
-
-
Scroll Inverter x 4
196 x 1 + 313 x 1 + 365 x 1 | -
Scroll Inverter x 4
Scroll Inverter x 5
196 x 1 + 313 x 1 + 365 x 1 | -
196 x 1 + 342 x 1 + 365 x 1 | -
19.05 (3/4)
19.05 (3/4)
19.05 (3/4)
41.28 (1-5/8)
-
41.28 (1-5/8)
41.28 (1-5/8)
-
-
200(220), 110(50)
200(220), 110(50)
200(220), 110(50)
R410A
R410A
R410A
7.0 x1 +10.5 x1 +14.0 x1
67, 89
7.0 x1 +10.5 x1 +14.0 x1
7.0 x1 +10.5 x1 +14.0 x1
65.77
65.77
65.77
68, 89
68, 90
(930 x1,695 x 765) x1 +
(1,295 x 1,695 x 765) x 2
205 x 1 + 268 x 1 + 325 x 1
(930 x1,695 x 765) x1 +
(1,295 x 1,695 x 765) x 2
(930 x1,695 x 765) x1 +
(1,295 x 1,695 x 765) x 2
205 x 1 + 268 x 1 + 325 x 1
205 x 1 + 301 x 1 + 325 x 1
-5~50 / -25~24
-5~50 / -25~24
-5~50 / -25~24
Alimentazione
Tipologia
Numero max interne collegabili
Ф, #, V, Hz
-
-
HP
Raffr.
kW
Risc.
kW
Raffr.
Risc.
A
Capacità
Assorbimento
Efficienza
Compressori
Ventilatore
Tubazioni
frigorifere
Refrigerante
Rumorosità
Dimensionali
HP
Capacità nominale
Corrente assorbita
nominale
Massima corrente assorbita
Magnetotermico
SEER
SCOP
Tipologia
Portata d'aria | Prevalenza
Tubazione liquido
Tubazione gas
Tubazioni gas (Recupero di calore)
Limiti installativi
Lunghezza Equiv., Dislivello Max
Tipologia
Carica di fabbrica
tCO
2
e
Pressione sonora, Potenza sonora
Dimensioni nette (LxAxP)
Peso netto
A
W/W
W/W
-
m
3
/min | Pa
Ф,mm(inch)
Ф,mm(inch)
Ф,mm(inch)
m
-
kg
tCO
2
e
dB(A)
mm
Kg
°C
Ф, #, V, Hz
-
-
HP
Raffr.
kW
Risc.
kW
Raffr.
Risc.
A
Campo di funzionamento Raffr. / Risc. (min~max)
Alimentazione
Tipologia
Numero max interne collegabili
MODELLO
62 HP (10+26+26)
64 HP (12+26+26)
66 HP (20+20+26)
3, 4, 380-415, 50
3, 4, 380-415, 50
3, 4, 380-415, 50
Pompa di Calore
Pompa di Calore
Pompa di Calore
64
62
64
64
64
66
173.6 / 173.6
(1)
179.2 / 179.2
(1)
184.8 / 184.8
(1)
195.3 / 164.0
(1)
201.6 / 169.6
(1)
207.9 / 180.0
(1)
131.19
134.47
134.87
101.63
104.59
96.55
141.2
145.0
146.0
175
175
175
-
-
-
-
-
-
Scroll Inverter x 5
181 x 1 + 365 x 2 | -
Scroll Inverter x 5
Scroll Inverter x 4
196 x 1 + 365 x 2 | -
313 x 2 + 365 x 1 | -
22.22 (7/8)
22.22 (7/8)
22.22 (7/8)
53.98 (2-1/8)
-
53.98 (2-1/8)
53.98 (2-1/8)
-
-
200(220), 110(50)
200(220), 110(50)
200(220), 110(50)
R410A
R410A
R410A
7.0 x 1 + 14.0 x 2
68, 90
7.0 x 1 + 14.0 x 2
10.5 x 2 +14.0 x1
73.08
73.08
73.08
69, 91
68, 90
(930 x1,695 x 765) x1 +
(1,295 x 1,695 x 765) x 2
205 x 1 + 325 x 2
(930 x1,695 x 765) x1 +
(1,295 x 1,695 x 765) x 2
(1,295 x 1,695 x 765) x 3
205 x 1 + 325 x 2
268 x 2 + 325 x 1
-5~50 / -25~24
-5~50 / -25~24
-5~50 / -25~24
Capacità
Assorbimento
Efficienza
Compressori
Ventilatore
Tubazioni
frigorifere
Refrigerante
Rumorosità
Dimensionali
HP
Capacità nominale
Corrente assorbita
nominale
Massima corrente assorbita
Magnetotermico
SEER
SCOP
Tipologia
Portata d'aria | Prevalenza
Tubazione liquido
Tubazione gas
Tubazioni gas (Recupero di calore)
Limiti installativi
Lunghezza Equiv., Dislivello Max
Tipologia
Carica di fabbrica
tCO
2
e
Pressione sonora, Potenza sonora
Dimensioni nette (LxAxP)
Peso netto
A
W/W
W/W
-
m
3
/min | Pa
Ф,mm(inch)
Ф,mm(inch)
Ф,mm(inch)
m
-
kg
tCO
2
e
dB(A)
mm
Kg
°C
Campo di funzionamento Raffr. / Risc. (min~max)
*Per le unità che beneficiano delle detrazioni fiscali o incentivi conto termico consultare il sito https://www.samsung.com/it/business/climate/environment
Condizioni di test: Capacità di raffreddamento nominale: temperatura aria interna 27°C (bulbo secco) / 19°C (bulbo umido); temperatura aria esterna 35°C (bulbo secco) / 24°C (bulbo umido).
Capacità di riscaldamento nominale: temperatura aria interna 20°C (bulbo secco) / 15°C (bulbo umido); temperatura aria esterna 7°C (bulbo secco) / 6°C (bulbo umido).
Lunghezza equivalente tubazione refrigerante: 7.5 m; Dislivello: 0 m - Valore di pressione sonora acquisito in camera anecoica. Il valore potrebbe variare in funzione delle condizioni installative.
(1)
In accordo con la normativa EN 14825 e con le condizioni di test EUROVENT.