0 1

SPECIFICHE UNITÀ ESTERNE

Unità esterne VRF innovative dotate di Intelligenza Artificiale nativa (AI),

nuovo Compressore con Advance Flash Injection (AFI

TM)

e ventilatore a profilo variabile.

D.F.

DETRAZIONI

FISCALI*

C.T.

CONTO

TERMICO*

1,695mm

DVM S2 POMPA DI CALORE - COMBINAZIONE STANDARD

930mm

1,295mm

765mm

MODELLO

32 HP (8+24)

34 HP (10+24)

36 HP (12+24)

3, 4, 380-415, 50

3, 4, 380-415, 50

3, 4, 380-415, 50

Pompa di Calore

Pompa di Calore

Pompa di Calore

58

32

61

64

34

36

89.6 / 89.6

(1)

95.2 / 95.2

(1)

100.8 / 100.8

(1)

100.8 / 89.6

(1)

107.1 / 95.2

(1)

113.4 / 100.8

(1)

62.65

68.46

69.88

55.08

58.48

60.40

73.0

78.0

80.0

80

90

90

-

-

-

-

-

-

Scroll Inverter x 3

151 x 1 + 365 x 1 | -

Scroll Inverter x 3

Scroll Inverter x 3

167 x 1 + 365 x 1 | -

196 x 1 + 365 x 1 | -

19.05 (3/4)

19.05 (3/4)

19.05 (3/4)

34.92 (1-3/8)

-

34.92 (1-3/8)

41.28 (1-5/8)

-

-

200(220), 110(50)

200(220), 110(50)

200(220), 110(50)

R410A

R410A

R410A

5.5 x1 +14.0 x1

65, 87

5.5 x1 +14.0 x1

7.0 x1 +14.0 x1

40.72

40.72

43.85

66, 88

66, 88

(930 x1,695 x 765) x1 +

(1,295 x 1,695 x 765) x 1

175 x 1 + 325 x 1

(930 x1,695 x 765) x1 +

(1,295 x 1,695 x 765) x 1

(930 x1,695 x 765) x1 +

(1,295 x 1,695 x 765) x 1

185 x 1 + 325 x 1

205 x 1 + 325 x 1

-5~50 / -25~24

-5~50 / -25~24

-5~50 / -25~24

Alimentazione

Tipologia

Numero max interne collegabili

Ф, #, V, Hz

-

-

HP

Raffr.

kW

Risc.

kW

Raffr.

Risc.

A

Capacità

Assorbimento

Efficienza

Compressori

Ventilatore

Tubazioni

frigorifere

Refrigerante

Rumorosità

Dimensionali

HP

Capacità nominale

Corrente assorbita

nominale

Massima corrente assorbita

Magnetotermico

SEER

SCOP

Tipologia

Portata d'aria | Prevalenza

Tubazione liquido

Tubazione gas

Tubazioni gas (Recupero di calore)

Limiti installativi

Lunghezza Equiv., Dislivello Max

Tipologia

Carica di fabbrica

tCO

2

e

Pressione sonora, Potenza sonora

Dimensioni nette (LxAxP)

Peso netto

A

W/W

W/W

-

m

3

/min | Pa

Ф,mm(inch)

Ф,mm(inch)

Ф,mm(inch)

m

-

kg

tCO

2

e

dB(A)

mm

Kg

°C

Ф, #, V, Hz

-

-

HP

Raffr.

kW

Risc.

kW

Raffr.

Risc.

A

Campo di funzionamento Raffr. / Risc. (min~max)

Alimentazione

Tipologia

Numero max interne collegabili

MODELLO

38 HP (14+24)

40 HP (16+24)

42 HP (18+24)

3, 4, 380-415, 50

3, 4, 380-415, 50

3, 4, 380-415, 50

Pompa di Calore

Pompa di Calore

Pompa di Calore

64

38

64

64

40

42

107.2 / 107.2

(1)

112.2 / 112.2

(1)

117.6 / 117.6

(1)

120.6 / 107.2

(1)

126.0 / 112.2

(1)

132.3 / 117.6

(1)

77.77

79.52

83.92

64.39

65.71

67.87

84.0

87.0

94.2

100

100

125

-

-

-

-

-

-

Scroll Inverter x 3

210 x 1 +365 x 1 | -

Scroll Inverter x 3

Scroll Inverter x 3

303 x 1 + 365 x 1 | -

324 x 1 + 365 x 1 | -

19.05 (3/4)

19.05 (3/4)

19.05 (3/4)

41.28 (1-5/8)

-

41.28 (1-5/8)

41.28 (1-5/8)

-

-

200(220), 110(50)

200(220), 110(50)

200(220), 110(50)

R410A

R410A

R410A

7.0 x1 +14.0 x1

67, 89

8.0 x1 +14.0 x1

8.0 x1 +14.0 x1

43.85

45.94

45.94

66, 88

66, 88

(930 x1,695 x 765) x1 +

(1,295 x 1,695 x 765) x 1

207 x 1 + 325 x 1

(1,295 x 1,695 x 765) x 2

(1,295 x 1,695 x 765) x 2

242 x 1 + 325 x 1

242 x 1 + 325 x 1

-5~50 / -25~24

-5~50 / -25~24

-5~50 / -25~24

Capacità

Assorbimento

Efficienza

Compressori

Ventilatore

Tubazioni

frigorifere

Refrigerante

Rumorosità

Dimensionali

HP

Capacità nominale

Corrente assorbita

nominale

Massima corrente assorbita

Magnetotermico

SEER

SCOP

Tipologia

Portata d'aria | Prevalenza

Tubazione liquido

Tubazione gas

Tubazioni gas (Recupero di calore)

Limiti installativi

Lunghezza Equiv., Dislivello Max

Tipologia

Carica di fabbrica

tCO

2

e

Pressione sonora, Potenza sonora

Dimensioni nette (LxAxP)

Peso netto

A

W/W

W/W

-

m

3

/min | Pa

Ф,mm(inch)

Ф,mm(inch)

Ф,mm(inch)

m

-

kg

tCO

2

e

dB(A)

mm

Kg

°C

Campo di funzionamento Raffr. / Risc. (min~max)

*Per le unità che beneficiano delle detrazioni fiscali o incentivi conto termico consultare il sito https://www.samsung.com/it/business/climate/environment

Condizioni di test: Capacità di raffreddamento nominale: temperatura aria interna 27°C (bulbo secco) / 19°C (bulbo umido); temperatura aria esterna 35°C (bulbo secco) / 24°C (bulbo umido).

Capacità di riscaldamento nominale: temperatura aria interna 20°C (bulbo secco) / 15°C (bulbo umido); temperatura aria esterna 7°C (bulbo secco) / 6°C (bulbo umido).

Lunghezza equivalente tubazione refrigerante: 7.5 m; Dislivello: 0 m - Valore di pressione sonora acquisito in camera anecoica. Il valore potrebbe variare in funzione delle condizioni installative.

(1)

In accordo con la normativa EN 14825 e con le condizioni di test EUROVENT.

42