0
2000
4000
6000
8000
Q US gpm
0
2000
4000
6000
Q IMP gpm
P
kP
a
300
H
m
H
f
t
100
30
65%
69%
Ø 46
5
76
%
9
0
78%
260
26
Ø 43
5
80%
8
0
78%
220
22
Ø 405/43
5
76%
7
0
69%
180
6
0
18
Ø 405/16°/43
5
65%
5
0
140
14
4
0
100
10
3
0
60
6
2
0
0
200 400
600
800 1000 1200 1400 1600 1800 2000 Q m3/
h
NPSH
m
Ø 405/16°/43
5
Ø 46
5
NPS
H
ft
3
10
8
2
6
4
1
0
200 400
600
800 1000 1200 1400 1600 1800 2000 Q m3/
h
kW
H
P
Ø 46
5
180
13
0
Ø 435
160
11
0
140
Ø 405/435
9
0
120
Ø 405/16°/43
5
100
7
0
8
0
5
0
0
200 400
600
800 1000 1200 1400 1600 1800 2000 Q m3/
h
0
100
200
300
400
500
Q l/
s
0
5000
10000
15000
20000
25000
30000
Q l/min
0
MEI non applicabile
Campo di temperatura del liquido: da -10°C a +120°C - Massima temperatura ambiente: +40°
C
0
P
kP
a
H
m
38
34
0
34
30
0
30
26
0
26
22
0
22
18
0
18
14
0
14
10
0
10
NPS
H
m
3,5
3
2,5
2
k
W
15
0
10
0
50
P
O
M
P
E
C
E
N
T
R
I
F
U
G
H
E
Ø 51
8
Ø 49
0
Ø 46
0
Ø 460/4
0
0
0
0
1
0
50
0
Per indice MEI fare riferimento alla sezione efficienza idraulica.
Le curve di prestazione sono basate su valori di viscosità cinematica
=
1 mm2/s e densità pari a 1000 kg/m3. Tolleranza delle curve secondo ISO9906
.
DATI ELETTRIC
I
(kW)
GRANDEZZA
MOTOR
E
ALIMENTAZ.
50 H
z
In
A
TIP
O
MOTORE
90
315M
3 x 400 V ~ Δ
159
IE3
110
315M
3 x 400 V ~ Δ
192
IE
3
KDN 350-500A
132
315L
3 x 400 V ~ Δ
(*)
IE3
160
315L
3 x 400 V ~ Δ
(*)
IE
3
(kW)
FLANGE (mm
)
(mm
)
GIUNTO
STANDAR
D
GIUNTO
SPAZIATOR
E
PESO
K
g
L
(mm)
PES
O
Kg
90
380
295
240
600
600
840
2490
1890
1305
1260
20x6
400
350
2658
1080
2659
1095
110
380
295
240
600
600
840
2490
1890
1305
1260
20x6
400
350
2675
1080
2676
1095
KDN 350-500A
132
380
295
240
600
600
840
2490
1890
1305
1260
20x6
400
350
2675
1080
2676
109
5
160
380
295
240
600
600
840
2700
2100
1305
1260
20x6
400
350
3202
1080
3203
109
5
Dati dimensionali ed elettrici in funzione del dimensionamento come da istruzioni a pag 183
.
( * ) Dati a richiesta.
DAB PUMPS si riserva il diritto di apportare modifiche senza obbligo di preavvis
o
259