3

2

Ø 22

4

6

5

4

0

10

20

30

40

50

60

70

Q m3/

h

Ø 290

6

8

Ø 270

6

4

0

10

20

30

40

50

60

70

Q m3/h

0

2

0

1

0

1

5

5

Q l/

s

KDN 80-250 - 4 POLI - POMPE NORMALIZZATE

0

200

400

600

800

1000

1200 Q l/mi

n

0

2

0

1

0

15

5

Q l/

s

0

200

400

600

800

1000

1200 Q l/mi

n

Campo di temperatura del liquido: da -10°C a +120°C - Massima temperatura ambiente: +40°

C

= 1450 1/min

KDN 65-400

= 1450 1/min

KDN 80-250

= 1450 1/min

0

40

80

120

160

200

240

280

320 Q US gp

m

0

40

80

120

160

200

240

Q IMP gp

m

P

kP

a

58

0

H

m

5

8

H

ft

19

0

18

0

54

0

5

4

Ø 40

8

35%

40

%

45%

17

0

50

0

48%

49

%

5

0

50%

Ø 39

0

52

%

16

0

46

0

4

6

15

0

42

0

4

2

Ø 37

0

14

0

13

0

38

0

3

8

Ø 35

0

12

0

34

0

3

4

11

0

10

0

3

0

10

0

0

10

20

30

40

50

60

7

0

Q m3/

h

NPSH

NPS

H

m

ft

Ø 35

0

Ø 40

8

4

12

3

8

2

4

1

0

10

20

30

40

50

60

7

0

Q m3/

h

kW

H

P

Ø 40

8

1

6

Ø 39

0

2

0

1

4

Ø 37

0

1

2

1

6

Ø 35

0

1

0

1

2

8

6

8

0

10

20

30

40

50

60

70

Q m3/

h

1

0

1

5

0

2

0

5

Q l/

s

0

200

400

600

800

1000

1200 Q l/min

0

100

200

300

400

50

150

250

350

450

Q US gp

m

0

100

200

30

0

50

150

250

350

400 Q IMP gpm

P

kP

a

24

H

m

24

MEI ≥ 0,4

0

H

f

t

8

0

22

Ø 264

60%

65

%

22

70%

7

0

72

%

20

20

73

%

18

Ø 244

6

0

18

72%

10

16

Ø 224

5

0

14

14

12

12

40

71

%

10

10

NPSH

m

2,5

2

1,5

1

0

20

40

60

80

100

Q m3/h

NPSH

Ø 224

Ø 26

4

f

t

1

0

8

6

4

0

20

40

60

80

100

Q m3/h

Q m3/h

kW

HP

7

6

5

4

3

Ø 26

4

Ø 244

Ø 224

9

8

7

6

5

4

0

20

40

60

80

100

Q m3/h

0

5

10

15

20

25

30 Q l/

s

0

200

400

600

800 1000 1200 1400 1600 1800 Q l/mi

n

KDN 80-25

0

7,5

132M

3 x 400 V ~ Δ

14,6

IE3

11

160M

3 x 400 V ~ Δ

20,5

IE

3

15

160L

3 x 400 V ~ Δ

28

IE3

DIMENSIONI GRUPPO (mm)

MODELLO

POTENZA

(kW)

A A2

H H1

H2

H3

L1

L3

B2

B3

D DNA

DIMENSIONI

FLANGE (mm

)

DNM L

(mm

)

GIUNTO

STANDAR

D

GIUNTO

SPAZIATOR

E

PESO

K

g

L

(mm)

PES

O

Kg

4

125

KDN 80-25

0

5,5

7,5

11

15

125

125

125

125

90

90

90

90

90

80

225

280

305

1250

840

540

490

24x4

125

80

1029

218

1170

218

80

225

280

305

1250

840

540

490

24x4

125

80

1099

234

1240

234

80

225

280

305

1250

840

540

490

24x4

125

80

1149

224

1290

23

9

80

225

280

305

1250

840

540

490

24x4

125

80

1294

261

1435

27

6

80

225

280

305

1250

840

540

490

24x4

125

80

1349

278

1490

293

Dati dimensionali ed elettrici in funzione del dimensionamento come da istruzioni a pag 183

.

DAB PUMPS si riserva il diritto di apportare modifiche senza obbligo di preavvis

o

21

1

P

O

M

P

E

C

E

N

T

R

I

F

U

G

H

E

Per indice MEI fare riferimento alla sezione efficienza idraulica.

Le curve di prestazione sono basate su valori di viscosità cinematica =

1 mm2/s e densità pari a 1000 kg/m3. Tolleranza delle curve secondo ISO9906.

DATI ELETTRIC

I

MODELLO

POTENZA

(kW)

GRANDEZZA

MOTOR

E

ALIMENTAZ.

50 H

z

In

A

TIP

O

MOTORE

4

112M

3 x 400 V ~ Δ

7,95

IE3

5,5

132S

3 x 400 V ~ Δ

10,6

IE3