Modello
AT-ECM 31
Tensione pilotaggio inverter (Vdc)
1
2
4
6
Velocità di rotazione
rpm
502
606
818
1016
8
10
1212
1300
1
2
502
606
AT-ECM 32
4
6
818
1016
8
10
1212
1300
1
2
502
606
AT-ECM 33
4
6
818
1016
Portata aria
m³/h
1025
1287
1819
2317
2810
3032
935
1175
1665
2120
2570
2775
876
1100
1555
1980
WT=85/75 °C Riscaldamento resa
kW
7,62
8,53
10,04
11,17
12,12
12,50
11,32
12,99
15,76
17,89
19,64
20,40
13,17
15,35
19,11
22,03
WT=85/75 °C Temperatura uscita aria
°C
37
34
31
29
28
27
50
47
43
40
37
36
59
56
51
48
WT=85/70 °C Riscaldamento resa
kW
6,86
7,66
9,00
9,98
10,84
11,15
10,27
11,75
14,20
16,08
17,66
18,29
11,98
13,93
17,30
19,90
WT=85/70 °C Temperatura uscita aria
°C
35
32
29
28
26
26
47
44
40
37
35
34
55
52
48
44
WT=80/60 °C Riscaldamento resa
kW
5,43
6,05
7,07
7,81
8,46
8,71
8,20
9,33
11,24
12,67
13,89
14,36
9,66
11,20
13,77
15,77
WT=80/60 °C Temperatura uscita aria
°C
30
29
26
25
24
23
41
38
35
32
31
30
47
45
41
38
Potenza assorbita motore
W 19,1
30,0
67,4
124,8
207,2
253,7
19,1
30,0
67,4
124,8
207,2
253,7
19,1
30,0
67,4
124,8
Potenza sonora (Lw)
Pressione sonora (Lp) (1)
dB(A)
29,5
55,5
63,5
69,0
73,0
75,5
51,5
55,5
63,5
69,0
73,0
33,5
51,0
Installaz. a parete: Altezza
m
2.5 ÷ 3,5
Installaz. a parete: Lancio
Installaz. a so
ffitto: Altezza
4
4
Installaz. a so
ffitto: Area d’in
fluenza
55
51,5
dB(A)
41,5
47,0
51,0
53,5
29,5
33,5
41,5
47,0
m
6,5
7,5
8,5
10
11
12
6,5
7
8
9
10
m
-
-
3,5
4
4
4,5
-
-
3,5
3,5
m²
-
-
50
55
60
60
-
-
50
50
60
(1)
Pressione sonora dB(A) riferita ad una distanza di 5m, fattore direzionale Q = 2, conforme alla norma EN 3744
.
WT Temperatura acqu
Modello
AT-ECM 41
Tensione pilotaggio inverter (Vdc)
1
2
4
6
Velocità di rotazione
rpm
518
613
810
1019
75,5
51,5
55,5
63,5
69,0
53,5
29,5
33,5
41,5
47,0
10,5
6
7
8
8,5
-
-
-
3,5
-
-
-
50
8
10
1218
1299
1
2
518
613
AT-ECM 42
4
6
810
1019
8
10
1218
1299
1
2
518
613
AT-ECM 43
4
6
810
1019
Portata aria
m³/h
1460
1780
2445
3155
3830
4110
1235
1505
2070
2670
3240
3475
1073
1310
1799
2321
WT=85/75 °C Riscaldamento resa
kW
10,44
11,52
13,34
14,93
16,20
16,66
15,01
16,88
20,17
23,09
25,37
26,23
16,61
19,04
23,39
27,22
WT=85/75 °C Temperatura uscita aria
°C
36
34
31
29
27
27
51
48
44
40
38
37
60
58
53
49
WT=85/70 °C Riscaldamento resa
kW
9,52
10,48
12,11
13,53
14,68
15,08
13,74
15,44
18,38
20,97
23,09
23,88
15,30
17,48
21,37
24,89
WT=85/70 °C Temperatura uscita aria
°C
34
32
29
28
26
26
48
45
41
38
36
35
57
54
50
46
WT=80/60 °C Riscaldamento resa
kW
7,67
8,42
9,71
10,82
11,70
12,04
11,15
12,51
14,87
16,89
18,53
19,15
12,55
14,27
17,38
20,14
WT=80/60 °C Temperatura uscita aria
°C
30
29
27
25
24
24
41
39
36
34
32
31
49
47
43
40
Potenza assorbita motore
W 21,0
32,0
65,0
119,0
192,0
253,0
21,0
32,0
65,0
119,0
192,0
253,0
21,0
32,0
65,0
119,0
Potenza sonora (Lw)
Pressione sonora (Lp) (1)
dB(A)
31,5
58,5
66,5
72,5
77,0
79,0
53,5
58,5
66,5
72,5
36,5
Installaz. a parete: Altezza
Installaz. a parete: Lancio
11
53,5
dB(A)
44,5
50,5
55,0
57,0
31,5
36,5
44,5
50,5
m
3 ÷ 4.
5
m
8,5
9,5
11
12,5
14
14,5
6,5
7
8,5
9,6
m
-
-
4
4,5
5
5
-
-
3,5
4
4
m²
-
-
60
65
70
70
-
-
50
55
60
(1)
Pressione sonora dB(A) riferita ad una distanza di 5m, fattore direzionale Q = 2, conforme alla norma EN 3744
.
WT Temperatura acqua
77,0
79,0
53,5
58,5
66,5
72,5
55,0
57,0
31,5
36,5
44,5
50,5
12,5
6
6,5
8
9
Installaz. a so
ffitto: Altezza
4,5
-
-
-
3,5
Installaz. a so
ffitto: Area d’in
fluenza
65
-
-
-
50
70 | Atlas EC
M
8
1
0
1212
130
0
2402
2592
24,51
25,5
9
45
4
4
22,10
23,04
42
41
17,50
18,19
36
36
207,2
253,
7
73,0
75,
5
51,0
53,5
9,5
10
3,5
4
50
55
8
1
0
1218
129
9
2816
3020
30,46
31,6
9
47
4
6
27,76
28,87
44
43
22,42
23,26
38
38
192,0
253,
0
77,0
79,
0
55,0
57,0
10
11
4
4
55
60