FSR

Technical details

4.216

FLEXWELL® Safety Pipe

Connecting fitting monitorable with collar and split loose flang

e

with monitorable sealing surface (Part 1), joining method: TIG welding/hard soldering

FLEXWELL® Safety Pipe

Type FSR 30/48 to FSR 127/175,

pressure stage PN 2

5

shrink sleeve

hard soldering

outer pip

e

connecting fitting

as end connection

with measurin

g

branch drill hol

e

d

1

ø

k

D

TIG welding

stainless steel inner pipe

l

appr.

L

Version:

Collar and split loose flange acc. to DIN EN1092-1

Material:

Threaded socket made of material no. 1.4404/1.4571

Flange made of material no. 1.4404/1.457

1

Installation instruction for split loose flange

:

The splitting of the loose flange needs to be installed staggered 90° in reverse order

.

Type

ID/OD DN

d1

Flange acc. to DIN EN 1092-1

l

L

Article No

.

DN D

ø k screws*

appr.

without measuring branch

split loose flange

mm

mm mm

pcs.

mm

mm

stainless steel 1.4404

AV-FSR 30/ 48 25

91

40 150 110 M16 x 80

4

85

222.5

1015893

AV-FSR 39/ 60 32

105

50 165 125 M16 x 90

4

85

222.5

1015911

AV-FSR 48/ 71 40

126

65 185 145 M16 x 90

8

90

242.5

1015928

AV-FSR 60/ 83 50

126

65 185 145 M16 x 90

8

90

242.5

1015952

AV-FSR 75/107 65

166

100 235 190 M20 x 110

8

132

277.5

1015966

AV-FSR 98/134 80

166

100 235 190 M20 x 110

8

136

295.5

1015983

AV-FSR 127/175 100

223

150 300 250 M24 x 120

8

140

299.0

1015999

Threaded socket can be delivered with or without measuring branch drill hole (Article No. for drill hole 1015565

)

* Screw length is given for the connector to a welding-neck flange acc. to DIN EN 1092-1.

Screws and nuts are not included in the delivery volume.

Only BRUGG solder Type BRL 8.50.34 may be used

!

08.12.2020 Subject to technical changes. Page 16